3. System Configuration and Wiring
Overall Wiring (Terminal block type)
Connecting Example of H-frame, 400 V type
• Wiring of Main Connector
Circuit Breaker (MCCB)
To protect power supply line from
overloading, install a wiring circuit breaker
rated to the capacity of the power supply.
Noise Filter (NF)
Removes external noise from the power
lines. And reduces an effect of the noise
generated by the servo driver.
Magnetic Contactor (MC)
Turns on/off the main power of the servo
driver.
Use coil surge suppression units together
with this.
• Never start nor stop the servo motor
with this Magnetic Contactor.
Reactor (L)
Reduces harmonic current of the main
power.
Connection to
24 VDC power supply for
regenerative resistor
external components
(to be supplied by customer)
B1
* Use a power
* Use a power
supply with
supply with
5 A or larger
5 A or larger
capacity.
capacity.
B2
Regenerative
resistor
(optional)
Remarks
• When you use an external
regenerative resistor, install an
external protective apparatus, such
as thermal fuse without fail.
• The regenerative resistor (optional)
Dynamic Brake
incorporates a fan, thermal fuse, and
resistor
thermostat. Once the thermal fuse
(
to be supplied by
blows out, it will not be restored.
customer
• Mount the regenerative resistor on
Remarks
incombustible material such as
metal.
• When you use an external dynamic brake resistor, install an
• For wiring of the circuit, refer to
"Wiring Diagram" on P.B23.
• Mount the dynamic brake resistor on incombustible
Note
The wiring indicated with the broken
• For wiring of the circuit, refer to "Wiring Diagram" on P.B23.
line shall be provided only when
• For an example of the recommended protective circuit, refer
required.
• Apply the voltage desig-
Mains
nated on the nameplate
Residual
current device
from the power source.
Symmetric current should be
5000 Arms or below.
If the short-circuit current on the
power source exceeds this
value, use a current-limiting
device (e.g. current-limiting fuse,
current-limiting circuit breaker or
transformer).
Charge lamp (LED)
Do not make displacement, wiring
or inspection while the LED is lit -
L1C
cause of electric shock.
24 VDC
* Use a power
supply with
power supply
5 A or larger
for control
capacity.
(
to be supplied by
customer
0V
24V
Connection
with control
power supply
Connection with input
L1
L2
L3
power supply
Magnetic Contactor (MC)
Turns on/off the dynamic brake resistor.
)
Use coil surge suppression units
together with this.
external protective apparatus, such as thermal fuse
without fail.
material such as metal.
to "Dynamic Brake" on P.B48.
− B14 −
3. System Configuration and Wiring
Overall Wiring (Terminal block type)
: High voltage
Wiring to Connector, X7
• Monitor output
)
24V
0V
DB1
DB2
L1
L2
L3
B1
B2
Ground
(earth)
Motor cable (Shield wire)
Connection to motor
driving phase and
ground
DC Power supply
for brake DC24V
(to be supplied
by customer)
PC
(to be supplied by customer)
Setup support software
"PANATERM"
Please download
from our web site.
Wiring to Connector, X1
• Connection to PC or host controller
X1
Wiring to Connector, X2
X2
X3
• Connection to RS232, RS485
or host controller
X4
Wiring to Connector, X3
X5
• Connection to Safety by-pass plug
X6
(Refer to P.B26)
CHARGE
Wiring to Connector, X4
• Connection to host controller
Wiring to Connector, X5
• Connection to feedback scale
Ground
Wiring to Connector, X6
terminal
• Connection to encoder
Junction cable for encoder
Remarks
• X1 to X7 are used for the secondary circuit. To
NC
U
V
W
connect these terminals to the primary power
supply (particularly, the 24 VDC power supply
for control, the 24 VDC power supply for
brake, and the 24 VDC power supply for
regenerative resistor), insulation is required.
U
-phase
Do not connect these terminals to the same
V
-phase
power supply.
W
-phase
Pin B1and B2
• When you connect an external regenerative
resistor, connect the external regenerative
resistor between B1 and B2, set up Pr0.16 to
1 or 2.
Pin DB1 and DB2
Brake cable
• When installing an external dynamic brake
resistor, connect the magnetic contactor (for
controlling) for external dynamic brake to
between LIC and DB1.
Remarks
• The voltage applied across DB1 and DB2
must be 300 VAC or below or 100 VDC or
below.
Note
• L1C is connected after the R-phase of the
noise filter.
• L1C is not indicated on the driver body.
Pin NC
• Do not connect anything.
− B15 −