9. Replacing quartz tube: Remove the black O-ring from the old
quartz tube and place it on the new tube. Place the new quartz tube
(8) into the water chamber (12) with the domed end first making sure
it is inserted and seated inside the quartz end holder. Only a small
portion will be exposed when it is seated correctly (11).
10. Reinstall and hand tighten the quartz seal compression nut (9) by
turning it clockwise.
11. Refill your spa.
12. System Test 1: Assure there is no water dripping from the seal
compression nut (9). If water is visible, STOP and tighten the
compression nut (9) using a pair of channel lock pliers to a maximum
of 1/4 turn. If that does not fix the leak, then repeat quartz tube
maintenance process from step 1 through step 11. Make sure there
is no water leaking before proceeding to step 13.
13. System Test 2: Reconnect the CLEARRAY unit to the controller.
Turn breaker back ON. Turn on the pump to circulate the water
through the CLEARRAY System. Wait for 5 minutes and assure no
water is dripping. If water is visible, STOP, fix the leak by repeating
quartz tube maintenance process from step 1 through step 12. Make
sure there is no water visible. Turn the pump and breaker OFF
BEFORE proceeding to step 14.
14. Reconnect the UV bulb socket (6) to the power cord socket (4) make
sure you use the latex glove provided when handling the UV bulb.
WARNING:
YOUR BARE HAND. Oil on your skin will cause hot spot on
!
the UV bulb and shorten the life of your UV bulb. Use the
provided latex glove to handle the UV bulb.
15. Slide the new UV bulb (7) back inside the quartz tube.
16. Reinstall the black bulb boot (5) back over the quartz seal
compression nut (9).
17. Reinstall the enclosure cover (2) and secure with the screws.
18. Properly dispose of the old UV bulb.
WARNING:
!
which contains mercury. Dispose of the bulb in accordance
with disposal laws. See www.lamprecycle.org.
19. Once power is activated you can check the ballast,
Figure 7, to see if the CLEARRAY System is
functioning. The power on (red) light indicates that the
CLEARRAY System is being provided power and
should always be on. The lamp on (green) light
indicates that UV bulb is activated.
DO NOT TOUCH THE NEW UV BULB WITH
This CLEARRAY System includes a UV bulb,
780 Series
DANGER!
TURN POWER
OFF! DO NOT
LOOK AT LIT BULB.
SEVERE EYE
DAMAGE OR BLINDNESS
CAN OCCUR!
Power
Lamp
on
on
FIGURE 7