Specifications; Installation Clearances - Lennox EL296DF045XV36B Unit Information

Icomfort - enabled el296dfv(x) series units
Hide thumbs Also See for EL296DF045XV36B:
Table of Contents

Advertisement

SPECIFICATIONS

Gas
Heating
Performance
High
Fire
Temperature rise range - °F
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
Low
Fire
Temperature rise range - °F
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
High static -
in. w.g.
Connections
Intake / Exhaust Pipe (PVC)
in.
Condensate Drain Trap (PVC pipe) - i.d.
with furnished 90° street elbow
with field supplied (PVC coupling) - o.d. 1/2 slip x 1/2 NPT
Indoor
Wheel nom. diameter x width - in.
Blower
Tons of add-on cooling
Air Volume Range - cfm
Electrical
Data
Blower motor full load amps
Maximum overcurrent protection
Shipping Data
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized
1

INSTALLATION CLEARANCES

NOTE - Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ANSI-
NOTE - In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA
Clearance for installation on combustible floor if Optional Downflow Combustible Flooring Base is installed be-
2
tween furnace and combustible floor. Not required in add-on cooling applications if installed in accordance with
local codes or National Fuel Gas Code ANSI-Z223.1 or CAN/CGA-149.1,.2. Do not install the furnace directly on
Model No. EL296DF045XV36B EL296DF070XV48B EL296DF090XV60C EL296DF110XV60C
AFUE
1
Input - Btuh
Output - Btuh
3.5 / 10.0
Input - Btuh
Output - Btuh
1.7 / 4.9
Heating
Cooling
Gas pipe size IPS
1/2 slip x 1/2 Mipt
Motor output - hp
545 - 1360
Voltage
lbs. - 1 package
NOTE - Filters and provisions for mounting are not furnished and must be field provided.
Sides
Rear
Top/Plenum
Front
Front (service/alcove)
Floor
Z223.1) or the National Standard of Canada CAN/CSA-B149.1 "Natural Gas and Propane Installation
54/ANSI-Z223.1) or applicable provisions of local building codes. In Canada flue sizing must conform to
the methods outlined in National Standard of Canada CAN/CSA-B149.1.
Allow proper clearances to accommodate condensate trap and vent pipe installation.
1
carpeting, tile, or other combustible materials other than wood flooring.
96%
96%
44,000
66,000
43,000
64,000
35-65
35-65
3.5 / 10.0
29,000
43,000
28,000
42,000
20 - 50
25 - 55
1.7 / 4.9
0.8
0.8
1.0
1.0
2 / 2
2 / 2
1/2
1/2
1/2
1/2
1/2 slip x 1/2 Mipt
1/2 slip x 1/2 NPT
10 x 9
11 x 10
1/2
3/4
2 - 3
2.5 - 4
575 - 1800
120 volts - 60 hertz - 1 phase
7.7
10.1
15
20
131
136
furnaces.
0 inches (0 mm)
1
0 inches (0 mm)
1 inch (25 mm)
0 inches (0 mm)
24 inches (610 mm)
Combustible
2
Code".
Page 2
96%
96%
88,000
110,000
85,000
106,000
40-70
45-75
3.5 / 10.0
3.5 / 10.0
57,000
72,000
56,000
70,000
30 - 60
35 - 65
1.7 / 4.9
1.7 / 4.9
0.8
1.0
2 / 2
2 / 2
1/2
1/2
1/2 slip x 1/2 Mipt
1/2 slip x 1/2 Mipt
1/2 slip x 1/2 NPT
1/2 slip x 1/2 NPT
11 x 11
11 x 11
1
3 - 5
3 - 5
890 - 2130
860 - 2180
12.8
12.8
20
164
176
0.8
1.0
1/2
1/2
1
20