9 - Use a utility knife to cut out the cabinet insulation for
the right side vent / air intake.
10 -Install the two 90° street elbows (provided) through the
side of the cabinet. The male side of each elbow
should extend down through the blower deck and con­
nect to the rubber fittings below. Once the elbows are
properly positioned, tighten each clamp.
11 -Peel protective backing from side vent sealing gaskets
(2) and apply to side vent sealing plates (2) as shown
in figure 19.
12 -Install the side vent sealing plates and gaskets on the
exterior of the cabinet as shown in figure 19. Secure
with six mounting screws (four reused and two pro­
vided from bag assembly). Holes are pre-punched in
the parts and cabinet, no drilling is required.
13 -Install sheet metal screws (provided) to seal extra two
holes in cabinet not used with side vent clamps.
IMPORTANT
Side vent sealing plates and side vent sealing gas­
kets must be used when converting to right side
venting. Failure to use gaskets and plates may lead
to improper operation of unit.
Top Vent Configuration
FIGURE 17
Exhaust/Air
Intake Connections
Pipe Clamp
Hose Clamp
Page 32
Patch Plate Top Cap
Sheet Metal
Patch Plate