Toshiba TOSVERT VF-nC3 Instruction Manual page 127

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-nC3:
Table of Contents

Advertisement

Reduction of rated current.
[Three phase/single phase 200 V class]
Ambient
VFNC3-
temperature
VFNC3S-
50 ° C or less
2001P/PL
50 ° C or less
2002P/PL
50 ° C or less
2004P/PL
40 ° C or less
2007P
40 ∼ 50 ° C
40 ° C or less
2007PL
40 ∼ 50 ° C
40 ° C or less
2015P/PL
40 ∼ 50 ° C
40 ° C or less
2022P
40 ∼ 50 ° C
40 ° C or less
2022PL
40 ∼ 50 ° C
50 ° C or less
2037P
[Single phase 100 V class]
Ambient
VFNC3S-
temperature
50 ° C or less
1001P
50 ° C or less
1002P
50 ° C or less
1004P
50 ° C or less
1007P
*
If ambient temperature exceeds 40°C, reduce current according to table above.
*
Default setting of PWM carrier frequency is 12kHz, but rated output current of rating label display at 4kHz.
If  is set to  or , however, the carrier frequency will decrease automatically with increase in current
in order to secure the rated current at frequencies of 4 kHz or less.
If  = , and current is increased to the automatic reduction level, the  alarm occurs, if current is
*
increased further  trips.
*
Random mode is exercised when the motor is operated in a low-frequency range where it produces annoying
acoustic noise.
If the carrier frequency () is set above 8 kHz, the random mode function will not be performed,
because the level of motor magnetic noise is low at high frequencies.
Carrier frequency
2 - 4 kHz
5 - 12 kHz
0.7 A
1.4 A
2.4 A
4.2 A
4.2 A
4.2 A
4.2 A
7.5 A
7.5 A
10.0 A
10.0 A
10.0 A
10.0 A
16.7 A
14.0 A
Carrier frequency
2 - 4 kHz
5 - 12 kHz
0.7 A
1.4 A
2.4 A
4.2 A
F-23
E6581595
13 - 16 kHz
0.7 A
0.7 A
1.4 A
1.4 A
2.4 A
2.4 A
3.6 A
3.0 A
3.2 A
2.8 A
3.2 A
2.8 A
3.2 A
2.8 A
7.5 A
7.1 A
7.1 A
7.1 A
8.5 A
7.5 A
7.5 A
7.5 A
9.1 A
8.0 A
7.5 A
7.5 A
14.0 A
13 - 16 kHz
0.7 A
0.7 A
1.4 A
1.4 A
2.4 A
2.4 A
4.0 A
4.0 A
6

Hide quick links: