An example of the connection of the open collector OUT terminal
(sink logic)
• Output terminal setting
6
6.1.2
: Speed reach detection band
• Function
Parameter setting of designated frequency and detection band
Parameter setting of output terminal selection
Note: Set to output to FLA-FLC-FLB terminals.
+24V
P24
OUT
Ry
NO
CC
Default outputs low-speed signal (ON signal) to OUT terminal. This setting must be changed to invert
the polarity of the signal.
[Parameter setting]
Title
Output terminal selection 1A (OUT)
Set to output to FLA-FLC-FLB terminals.
Output of designated frequency reach signal
When the output frequency becomes equal to the setting by designated frequency ±, an ON or
OFF signal is generated.
Title
Function
Speed reach detection band
Title
Function
Output terminal
selection 1A
(OUT)
An example of the connection of the relay output terminals
FLA
FLB
FLC
Function
0-255
(See 11.7.)
0.0 ∼ (Hz)
Adjustment range
0-255
6: RCH (designated frequency - ON signal), or
(See 11.7.)
7: RCHN (designated frequency - OFF signal)
F-2
+24V
RY
Adjustment range
Default setting
4 (ON signal)
5 (OFF signal)
Adjustment range
Default setting
Setting value
E6581595
or
2.5