Bosch DS12R Installation And Operation Manual page 15

Self-contained control panel
Table of Contents

Advertisement

.
Table 3: Programming Values (continued)
Program
Address
Description
81
RF Key fob 1 ID Number
82
RF Key fob 2 ID Number
83
RF Key fob 3 ID Number
84
RF Key fob 4 ID Number
85
RF Key fob 5 ID Number
86
RF Key fob 6 ID Number
87
Send trouble report
99
Return to factory default values
Table 4: Zone Types
Type
Description
Instant
When the system is armed, faulting an Instant zone causes an alarm.
Delay
When the system is armed, faulting this zone causes an alarm after the Entry or Exit Delay time setting
expires.
24-hour
This zone is always active. Faulting this zone always causes an alarm.
Follower
When the system is armed and a Delay zone is not faulted, faulting this zone causes an alarm. If a Delay
zone is faulted, an alarm occurs after the delay time.
Silent Zone
When the system is armed, faulting a Silent zone causes a Silent alarm. The keypad is silent and shows no
alarm output, but the DS12R sends an alarm event to the central station.
Perimeter Zone
When the perimeter is armed, faulting a Perimeter zone causes an alarm.
Perimeter Delay
When the perimeter is armed, faulting this zone causes an alarm after the Entry or Exit Delay time setting
Zone
expires.
Bypass
If a zone is programmed for Bypass, it does not cause an alarm when it is faulted. If a system is force
armed, the zone that is bypassed is not active.The bypass condition clears when the system is disarmed. A
24-hour zone type cannot be bypassed. All other zone types can be bypassed.
Swinger Bypass
If a zone is programmed for Swinger Bypass, it causes an alarm only the first time it is faulted. All other
faults during this armed period are ignored. The Swinger Bypass clears when the system is disarmed.
Request-to-exit
When this zone is disarmed, activating this input activates the output programmed to follow the Door
(REX)
Unlock Time setting.
If Zone 12 is programmed to 8=REX, Door Unlock activates after Zone 12 is activated.
Bosch Security Systems, Inc. | 5/08 | F01U081956-01
DS12R | Installation and Operation Guide | Programming
Factory Default Value
Program Value
000000000
000000000 = Disabled
Allows 000000001 to 999999999 ID numbers
000000000
000000000 = Disabled
Allows 000000001 to 999999999 ID numbers
000000000
000000000 = Disabled
Allows 000000001 to 999999999 ID numbers
000000000
000000000 = Disabled
Allows 000000001 to 999999999 ID numbers
000000000
000000000 = Disabled
Allows 000000001 to 999999999 ID numbers
000000000
000000000 = Disabled
Allows 000000001 to 999999999 ID numbers
0
0 = Disabled
1 = Enabled
18
Enter this value to return all values except the Master
Code to the factory default values. Use this function for
installation and maintenance. Refer to Section 3.6
Resetting Default Values on page 17. to return the
Master Code to its default value.
15