2.2

Wiring the DS12R

2.2.1.

System Wiring

Warning: Remove power from all devices
before connecting or removing the
DS12R.
Connect devices as shown in Figure 4. If the DS12R is
the last device on the RS-485 bus, connect a 120 Ω
end-of-line (EOL) resistor in parallel with the
RS-485.
Only the last device on the RS-485 bus
requires a 120 Ω EOL resistor (included
with the MTGW CAN-RS-485 BUS
Gateway).
Figure 4: System Wiring
Ω
1- 120
EOL resistor
Figure 5 shows the three DS12R terminal strips. Refer
to Table 2 for wiring connections.
Figure 5: DS12R Terminal Strips
1- Terminal Strip 1 (TS1)
2- Terminal Strip 2 (TS2)
3- Terminal Strip 3 (TS3)
Bosch Security Systems, Inc. | 5/08 | F01U081956-01
DS12R | Installation and Operation Guide | Installation
Table 2: Terminal Wiring
Terminal Strip 1 (TS1)
Label
Description
Z1
Zone 1
COM
Common (earth ground)
Z2
Zone 2
Z3
Zone 3
COM
Common (earth ground)
Z4
Zone 4
Z5
Zone 5
COM
Common (earth ground)
Z6
Zone 6
Z7
Zone 7
COM
Common (earth ground)
Z8
Zone 8
Terminal Strip 2 (TS2)
Label
Description
+
Power + (12 VDC)
-
Power – (common)
A
RS-485 A Terminal
B
RS-485 B Terminal
KS
Keyswitch input
P01
Solid State Output 1
COM
Solid State Output Common
P02
Solid State Output 2
Terminal Strip 3 (TS3)
Label
Description
Z9
Zone 9
COM
Common (earth ground)
Z10
Zone 10
Z11
Zone 11
COM
Common (earth ground)
Z12
Zone 12
INS
Instant zone
NO
Alarm output (normally open)
C
Alarm output (common)
NC
Alarm output (normally closed)
RF1
RF receiver interface
RF2
RF receiver interface