16
OPTIONAL PARTS
16-1. AIR CLEANING FILTER
AIR CLEANING FILTER removes fine dust of 0.01 micron from air by means of static electricity.
Normal life of AIR CLEANING FILTER is 3 months. However, when it becomes dirty, replace it as soon as possible.
Clogged AIR CLEANING FILTER may reduce the air conditioner capacity or cause frost on the air outlet.
DO NOT reuse AIR CLEANING FILTER even if it is washed.
DO NOT remove or attach AIR CLEANING FILTER during unit operation.
Model
MSC-07RV-
MSC-09RV-
MSC-12RV-
16-2. DEODORIZING FILTER
DEODORIZING FILTER removes ammonia and hydrogen sulphide emitted from tobacco, and odors of pets.
Clean DEODORIZING FILTER every two weeks. If the filter is particularly dirty, clean the filter more often.
For cleaning, soak the filter in warm water for a while, and then wash and rinse it. Dry the filter in the shade
thoroughly.
When the filter color is still dark even after cleaning, replace the filter with a new one.
Replace the filter at least once a year.
Model
MSC-07RV-
MSC-09RV-
MSC-12RV-
DEODORIZING FILTER and AIR CLEANING FILTER can be attached on either side.
16-3. Different-diameter pipe
MXZ-18RV
Model name
For same
MAC-451JP
diameter
pipes
MAC-460JP
NOTES: 1 As liquid pipe diameter is the same for indoor unit and outdoor unit, L-joint is not required.
2 Using MAC-460JP substitutes for pipe bending and makes piping nice-looking.
3 Connect it directly to indoor unit gas pipe.
MXZ-32RV
Model name
MAC-454JP
For different-
diameter
MAC-455JP
pipes
MAC-456JP
Part No.
E1
E1
MAC-1300FT
E1
Part No.
E1
E1
MAC-1800DF
E1
Connects outdoor unit union and gas pipe.
Length
Connected pipes
diameter
[9.52 - [12.7
155.5
(3/8) (1/2)
[9.52 - [9.52
155.5
(3/8) (3/8)
Connected pipes
Model code
diameter (mm)
{9.52 — {12.7
51H-454
(3/8)
{12.7 — {9.52
51H-455
(1/2)
{12.7 — {15.88
516456
(1/2)
To outdoor unit
Diameter
Diameter
A
B
C
[12.7
[9.52
(1/2)
(3/8)
[9.52
[9.52
(3/8)
(3/8)
Length
A
{9.52
(3/8)
(1/2)
{12.7
(3/8)
(1/2)
{12.7
(1/2)
(5/8)
184
A
connection
B
Length
Length
B
C
{12.7
69
(1/2)
A
{9.52
65
(3/8)
{15.88
66.5
(5/8)
Unit : mm (inch)
C
To indoor unit
connection
Unit : mm (inch)
B
C