Mitsubishi Electric MSC-07RV Service Manual page 160

Wireless / multi system / inverter controlled multi system type, split-type / heat pump air conditioners
Hide thumbs Also See for MSC-07RV:
Table of Contents

Advertisement

OPERATING PROCEDURE
5. Removing the compressor. (A,B)
(1) Remove the cabinet. (Refer to 1)
(2) Remove the relay panel. (Refer to 2)
(3) Remove the terminal cover.
(4) Pull out lead from the compressor.
(5) Remove the suction pipe welded section and discharge
pipe welded section using a burner. Pull out when the
welding melts.
(6) Remove the sound proof felt.
(7) Remove the compressor set nuts.
(8) Remove the compressor.
6. Removing the compressor. (C,D)
(1) Remove the cabinet. (Refer to 1)
(2) Remove the relay panel. (Refer to 2)
(3) Remove the screws fixing rear panel. (Refer to photo 2)
(4) Remove the rear panel.
(5) Remove the terminal cover.
(6) Pull out lead from the compressor.
(7) Remove the suction pipe welded section and discharge
pipe welded section using a burner. Pull out when the
welding melts.
(8) Remove the sound proof felt.
(9) Remove the compressor set nuts.
(10) Remove the compressor.
Photo 7
Sound proof felt Suction pipe
160
PHOTOS
Terminal cover
Discharge pipe

Hide quick links: