Programming Q Parameters | Additional functions
Group
Gruppen-
name
nummerID
Activate machine parameter subfile
1020
Configuration settings for cycles
1030
Write or read PLC data synchronously in real time
2000
HEIDENHAIN | TNC 640 | Conversational Programming User's Manual | 10/2017
Systemdaten-
Index
nummer
13
QS parameter
no.
1
-
-
10
Marker no.
20
Input no.
30
Output no.
40
Counter no.
50
Timer no.
60
Byte no.
70
Word no.
80
Double-word
no.
Description
Has a machine parameter subfile with path
from QS number (IDX) been loaded?
1 = Yes
0 = No
Display spindle does not rotate error
message?
(CfgGeoCycle/displaySpindleErr)
0 = no, 1 = yes
Check the algebraic sign for depth error
message! display?
(CfgGeoCycle/displayDepthErr)
0 = no, 1 = yes
PLC markers
General note for NR10 to NR80:
The functions are executed synchronously
in real time, i.e. the function is not executed
until the corresponding point is reached in the
program.
HEIDENHAIN recommends using the WRITE
TO PLC or READ FROM PLC commands
instead of ID2000 and synchronizing the
execution in real time by using FN20: WAIT
FOR SYNC.
PLC input
PLC output
PLC counter
PLC timer
PLC byte
PLC word
PLC double word
10