3900 Series Digital
Deskphone External Alerter
and Recording Interface
Installation
and
Application Guide
External Alerter and Recording Interface Installation And Application Guide
1

Advertisement

loading

Summary of Contents for Avaya 3902

  • Page 1 3900 Series Digital Deskphone External Alerter and Recording Interface Installation Application Guide External Alerter and Recording Interface Installation And Application Guide...
  • Page 2 Important: CONCERNING THE LEGALITY OF RECORDING CONVERSATIONS The External Alerter and Recording Interface does not provide record beep tones and its use to record conversations may violate local laws. It is the responsibility of the user to ensure compliance with local laws concerning the recording of conversations. CONCERNING SAFETY &...
  • Page 3 About the External Alerter and Recording Interface The External Alerter and Recording Interface connect s to any 3900 series Digital Telephone except the 3901 which has no accessory port. In order to use the External Alerter And Recording Interface accessory, the telephone must be equipped with the 3900 series ACM (Accessory Connection Module) in the footstand and the power supply (purchase separately).
  • Page 4: Installation

    Installation The External Alerter and Recording Interface can be installed in the large or small port of a 3902, 3903 , 3904 or 3905 Digital Telephone. Three output connectors are provided on the back of the External Alerter and Recording Interface cartridge as shown in Figure 1.0. There...
  • Page 5 Installation (Cont'd) 1. The RJ12 modular jack provides access to all three output signals and is intended for wiring connection to remotely located equipment (not on the desktop). Connections are as follows: Position Wire color Function 3, 4 center pair Green, Red Call status relay contact 2, 5 2...
  • Page 6 Application Example 1 Loud ringer connected to the External Alerter and Recording Interface through the RJ12 jack. Figure 2.0 Note: Such as 1825P Duet Plus from Algo Communication Products Ltd. or equivalent. For more information: www.algo.ca or (604) 454-3790. External Alerter and Recording Interface Installation And Application Guide...
  • Page 7 Application Example 2 Desk top voice recording Figure 3.0 External Alerter and Recording Interface Installation And Application Guide...
  • Page 8 Application Example 3 Call in progress indicator Figure 4.0 Note: Such as 1126P Strobe Li ght or 1127P Desktop V isual Alerter (shown) from Algo Communication Products Ltd. or equivalent. For more information: www.algo.ca or (604) 454-3790. External Alerter and Recording Interface Installation And Application Guide...
  • Page 9 Application Example 4 Remote voice recording using Call Status Figure 5.0 External Alerter and Recording Interface Installation And Application Guide...
  • Page 10: Specifications

    Specifications Ring relay contact Normally open, max 50 mA 30 V Call status relay contact Normally open, max 50 mA 30 V Record audio level (RJ12 jack) Nominal -12dBm, 600 Ohm Record audio level (3.5mm jack) Nominal -52 dBu, microphone level Operating T emperature 0 °C to 50°C, (32°...
  • Page 11: Troubleshooting

    Troubleshooting Ensure that the ACM (Accessory Connection Module) power supply is connected to the telephone and plugged into a working AC outlet. Ensure that the External Alerter and Recording Interface is completely inserted and the release latch is engaged. If using the RJ12 jack, ensure that the modular cord contains 6 wires. If using the 2.5mm or 3.5mm jacks ensure that the plugs are fully inserted.