Airflow Data (cont.)
AVPTC48D
0.1
A
Low
910
B
Low
1050
C
Low
1155
D
Low
1215
A
High
1370
B
High
1570
C
High
1720
D
High
1840
AVPTC60D
0.1
A
Low
1205
B
Low
1375
C
Low
1445
D
Low
1535
A
High
1615
B
High
1825
C
High
1930
D
High
2040
Note:
The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate.
• Use the CFM adjustment factors of .98 for horizontal left, .95 for horizontal right & .96 for downflow orientations.
Airflow data indicated is at 230V without air filter in place.
Electric Heat Airflow
HTR kW
9
10
3
ON
ON
5
ON
ON
6
ON
OFF
8
ON
OFF
10
OFF
ON
15
OFF
ON
19*
OFF
OFF
20
21 or 25*
OFF
OFF
Note: Airflow data shown applies to the electric heat only in either legacy mode or communicating mode operation
--- indicates Not Rated
* Within thermostat user menu, CTK0* communicating thermostat will display 20kW for OFF- OFF- ON dipswitch selection,
21kW for OFF-OFF-OFF dipswitch selection.
† For match up with a 2 ton outdoor unit: Heater kit application shall not exceed 10 kW.
Airflow for 5 kW up to 10 kW heater kits shall be set to 850 cfm speed tap of ON-ON-ON.
†† For match up with a 3 ton outdoor unit: Heater kit application shall not exceed 15 kW.
Airflow for 5 kW up to 15 kW heater kits shall be set to 1300 cfm speed tap of ON-OFF-ON.
††† For match up with a 3.5 ton outdoor unit: Heater kit application shall not exceed 20 kW.
Airflow for 5 kW up to 20 kW heater kits shall be set to 1500 cfm speed tap of ON-OFF-OFF
** 3 kW heater kit is not applicable for this indoor application.
6
0.2
0.3
0.4
910
900
895
1045
1035
1030
1145
1140
1135
1210
1200
1195
1360
1350
1345
1560
1550
1545
1710
1700
1695
1820
1800
1785
0.2
0.3
0.4
1205
1210
1205
1370
1365
1360
1445
1450
1445
1530
1525
1520
1615
1610
1610
1820
1815
1810
1925
1920
1915
2030
2025
2020
AVPTC
AVPTC
11
24B14A*
30C14A*
ON
730
730
OFF
780
780
ON
850
850
OFF
950
950
ON
1025
1025
OFF
---
---
---
---
ON
---
---
OFF
---
---
www.goodmanmfg.com
0.5
0.6
0.7
885
880
875
1025
1020
1015
1130
1125
1120
1190
1185
1180
1340
1330
1325
1535
1530
1525
1685
1680
1670
1775
1760
1745
0.5
0.6
0.7
1205
1200
1195
1360
1355
1355
1445
1440
1440
1520
1515
1510
1605
1605
1600
1810
1805
1805
1915
1910
1905
2015
2010
2005
AVPTC
AVPTC
AVPTC
36C14A*
42D14A†
48C14A*
---
850**
---
850
1250
850
900
1300
900
1000
1500
1000
1200
1550
1200
1440
1720
1440
1500
---
1500
---
1800
1500
---
---
---
0.8
0.9
870
850
1010
1010
1120
1115
1175
1170
1325
1320
1520
1515
1670
1665
1740
1735
0.8
0.9
1195
1195
1350
1350
1440
1435
1510
1510
1600
1600
1805
1800
1905
1900
2005
2000
AVPTC
AVPTC
48D14A††
60D14A†††
---
---
1250
1250
1300
1300
1500
1500
1550
1550
1720
1780
---
---
1815
1850
1850
1850
SS-GAVPTC

Hide quick links:

Advertisement

loading