LG WM2801H Series Training Manual page 34

Front-loader washer
Hide thumbs Also See for WM2801H Series:
Table of Contents

Advertisement

TRAINING MANUAL
A
Prewash valve opens, cold water is supplied.
B, D, and F
Hot valve opens to raise the water temperature to 131° F.
C, E, and G
Cold valve opens to lower the water temperature to 122° F.
H
No water is supplied because the water level reaches the target.
Example 1
In example 2, HOT / COLD temperatures are chosen for a NORMAL cycle. The prewash
valve is opened and cold water is supplied briefly, then the hot valve is opened and water
fills the tub to the target water level. This water never reaches the set point, so the
heater is energized. When the water temperature reaches 122° F, the heater is turned off.
Example 2
A
Prewash valve opens, cold water is supplied.
B
Hot valve opens to raise the water temperature to 122° F.
C
No cold water is supplied because it has already reached the target level.
D
Heater is not turned on because the target temperature of 122° F is reached.
WM2801H*A
Page 34
WM2801H*A
Washing Machine

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents