4.2.25 Plate Side R Assy

(1) Separate the Plate Side R Assy. (Refer to 4.2.23)
(2) Remove two screws (Silver) ① . Remove the Guide-Cassette-R ② .
(3) Remove two screws (Black) ③ . Remove the Connector ④ .
(4) Remove four screws (Silver) ⑤ . Remove the Plate-ID-Gear ⑥ , Gear-
Idle-Z21 ⑦ , Gear-Idle-Z30-33 ⑧ .
(5) Remove the screw (Silver) ⑨ . Remove the Holder-Switch ⑩ and Micro
switch ⑪ .
(6) Remove two screws (Silver) ⑫ , the screw (Black) ⑬ . Remove the Guide-
ID-R ⑭ and Motor-Fan (40×15) ⑮ , Board-974 ⑯ , Spring-ID Lock R ⑰ .
(7) Remove the screw(Silver) ⑱ and screw(M4) ⑲ .Remove the Guide-Cable
⑳ .
(8) Installing is performed by the inverse procedure with removing.
Note!
1. Beware of not to touch the DC motor inattentively (Do not rotate motor).
2. Install Motor-FAN (40×15) ⑮ with the label side inward and with its notch
fitted to the appropriate projection of Guide-ID-R ⑭ .
3. While removing or installing FAN, do not press impeller of the FAN as
shown by the following photo. In case of the impeller unfastened by
mistake, do not reuse it and install a new FAN.