Oki Data CONFIDENTIAL
4.2.16 Cover Assy Stacker
(1) Remove the Scanner unit. (Refer to 4.2.8)
(2) Remove the Plate-Shield and CU/PU Board. (Refer to 4.2.3)
(3) Remove the Guide Cable . (Refer to 4.2.14)
(4) Remove the screw ① .
45762101TH Rev.1
(5) Remove the two screws (Silver) ② . Remove the Cover-Eject ③ and Plate-
Rear ④ .
(At this moment, Head cable is also removed.)
(6) With the Cover Assy Stacker closed, detach Lever-Link-Fuser ⑤ (on both
sides) from the Cover Assy Stacker.
①
②
④
②
③
4.REPLACEMENT OF PARTS
⑤
Release lever
Closed the Cover Assy Stacker
4-35