Test Patterns

On the main Diagnostics menu, touch the Test Patterns button to display the Test
Patterns menu, which contains buttons for selecting the different available test
patterns: Display Color Bars, Display Vertical Lines, Display Gray Scale,
Display Grid Pattern and Display Test Pattern. Touch Back to return to the main
Diagnostics menu.
"Test Patterns" Menu
Mic Test
On the main Diagnostics menu, touch Mic Test to perform a test of the
TPMC-4SM's built-in microphone. The button label changes to
RECORDING/PLAYBACK. Speak into the microphone on the front of the
TPMC-4SM (for five seconds), and the recording is played back to confirm the
microphone is functioning. After playback, the button reverts to its original Mic Test
label. Touch Back to return to the Panel Setup Options menu.
User Project Mode Off / User Project Mode On
On the Panel Setup Options menu, the User Project Mode Off button toggles
between this mode and User Project Mode On. User Project Mode Off is the
default state for using the TPMC-4SM with the Crestron Fusion Cloud software
interface.
Save & Exit
On the Panel Setup Options menu, touch Save & Exit to save all settings, to exit
the setup screens, and to return to the main project.