Installing and Removing a SIP

Deactivating a SIP

To deactivate a SIP and its installed SPAs prior to removal of the SIP, use the following command in
global configuration mode:
Command
Router(config)# hw-module slot
slot-number stop
For more information about chassis slot numbering, see the
SPAs" section on page
Reactivating a SIP
If you did deactivate the SIP using the hw-module slot stop command, then you do not need to reactivate
the SPAs after an OIR of the SIP. The installed SPAs automatically reactivate upon reactivation of the
SIP in the Cisco ASR 1000 Series Router.
For example, consider the case where you remove a SIP from the Cisco ASR 1000 Series Router to
replace it with another SIP. You reinstall the same SPAs into the new SIP. When you enter the
hw-module slot start command on the Cisco ASR 1000 Series Router, the SPAs automatically reactivate
with the new SIP.
To activate a SIP and its installed SPAs after the SIP has been deactivated, use the following command
in global configuration mode:
Command
Router(config)# hw-module slot
slot-number start
For more information about chassis slot numbering, see the
SPAs" section on page
Verifying Deactivation and Activation of a SIP
To verify the deactivation of a SIP, enter the show platform command in privileged EXEC
configuration mode. Observe the State field associated with the SIP that you want to verify.
The following example shows that the Cisco ASR1000-SIP10 located in slot 1 is deactivated.
OL-14126-03
2-2.
2-2.
Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Hardware Installation Guide
Purpose
Shuts down any installed interfaces, and deactivates the
SIP in the specified slot, where:
slot-number—Specifies the SIP chassis slot number
where the SIP is installed.
stop—Deactivates the SIP and places it in reset
mode.
"Identifying Slots and Subslots for SIPs and
Purpose
Activates the SIP in the specified slot and its installed
SPAs, where:
slot-number—Specifies the SIP chassis slot number
where the SIP is installed.
start—Activates the SIP and removes it from reset
mode.
"Identifying Slots and Subslots for SIPs and
Online Insertion and Removal