2-1-6

Connection between Communications Cables and Connectors

Connect the communications cable and the connector by wiring them straight as shown below.
Pin No.
Wire color
1
White-Green
2
Green
3
White-Orange
4
Blue
5
White-Blue
6
Orange
7
White-Brown
8
Brown
Connector
Shielded cable*
hood
* Connect both ends of cable shielded wires to the connector hoods.
Additional Information
There are 2 types of wiring standards for Ethernet cables: "T568A" and "T568B."
The figure above shows a wiring method conforming to the standard "T568A," but a wiring
method conforming to the standard "T568B" can also be used.
EtherCAT Communication Unit USER'S MANUAL (3G3AX-MX2-ECT)
2 Starting a Sample System
Wire color
White-Green
Green
White-Orange
Blue
White-Blue
Orange
White-Brown
Brown
Shielded cable*
Pin No.
1
2
2
3
4
5
6
7
8
Connector
hood
2 - 7