1B01 hex
258th fixed transmit PDO mapping
Sub-index 0: Number of objects
Setting range: 
Size: 1 byte (U8)
Sub-index 1: 1st Input Object to be mapped
Setting range: 
Size: 4 bytes (U32)
Sub-index 2: 2nd Input Object to be mapped
Setting range: 
Size: 4 bytes (U32)
• The PDO allocation when a fixed profile is used.
• The following objects are mapped.
• Status information (5100 hex), Output frequency monitor (5110 hex)
1BFF hex
512th transmit PDO mapping
Sub-index 0: Number of objects in this PDO
Setting range: 
Size: 1 byte (U8)
Sub-index 1: 1st Input Object to be mapped
Setting range: 
Size: 4 bytes (U32)
• This is a mapping object to notify that the EtherCAT Communication Unit has detected an error.
• 2002 hex-01 hex: Sysmac Error Status has been mapped.
• When the Machine Automation Controller NJ501-1x00 series is connected, assign this object to
1C13 hex: Sync manager 3 PDO assignment.
• By default, Sysmac Studio assigns this object automatically.
5-5-3

Sync Manager Communication Objects

Objects 1C00 to 1C33 hex set how to use the EtherCAT communications memory.
1C00 hex
Sync Manager communication type
Sub-index 0: Number of used SM channels
Setting range: 
Size: 1 byte (U8)
Sub-index 1: Communication Type SM0
Setting range: 
Size: 4 bytes (U8)
Sub-index 2: Communication type SM1
Setting range: 
Size: 4 bytes (U8)
Sub-index 3: Communication type SM2
Setting range: 
Size: 4 bytes (U8)
Sub-index 4: Communication type SM3
Setting range: 
Size: 4 bytes (U8)
• The Sync Manager has the following settings.
• SM0
: Mailbox reception (master to slave)
• SM1
: Mailbox send (slave to master)
• SM2
: Process data output (master to slave)
• SM3
: Process data input (slave to master)
EtherCAT Communication Unit USER'S MANUAL (3G3AX-MX2-ECT)
Unit: 
Default setting: 2
Access: RO
Unit: 
Default setting: 51000010 hex
Access: RO
Unit: 
Default setting: 51100010 hex
Access: RO
Unit: 
Default setting: 01 hex
Access: RO
Unit: 
Default setting: 20020108 hex
Access: RO
Unit: 
Default setting: 04 hex
Access: RO
Unit: 
Default setting: 01 hex
Access: RO
Unit: 
Default setting: 02 hex
Access: RO
Unit: 
Default setting: 03 hex
Access: RO
Unit: 
Default setting: 04 hex
Access: RO
5 CiA402 Drive Profile
All
PDO map: Not possible
PDO map: Not possible
PDO map: Not possible
All
PDO map: Not possible
PDO map: Not possible
All
PDO map: Not possible
PDO map: Not possible
PDO map: Not possible
PDO map: Not possible
PDO map: Not possible
5
5 - 13