The control panel display
does not illuminate when
POWER I/O is in the ON,
marked "I", position.
Heat rollers do not turn when
I press the Run button.
Heat rollers only turn if I use
the foot switch.
Rear controls do not
operate.
Laminated items exhibit
curling.
Adhesive deposited on heat
rollers.
7-2
POSSIBLE CAUSE
Laminator not connected to electrical
supply.
Safety shield is not properly installed.
Feed table not properly installed
Emergency Stop is engaged
Laminator is in foot switch mode.
Rear controls are not enabled.
Safety shield is not installed in rear
position.
Tension between the top and bottom film
roll is unequal.
Tension on top or bottom roll of film is
too film loose.
Bottom film roll may be improperly
loaded.
Top and bottom film webs not aligned.
Laminate improperly loaded.
Operating Instructions
CORRECTIVE ACTION
Insert attachment plug into receptacle.
Remove safety shield and properly
replace it.
Tilt feed table and properly replace it.
Pull out on the emergency stop push
button.
Disengage the foot switch mode.
Enable rear controls.
Install the safety shield.
Adjust film tension.
Adjust film tension.
Make sure bottom roll of film is around
idler bar and the it is in the normal
operating position.
Release heat and pull roller pressure,
align the rolls of film.
Adhesive (matte) side of laminate film
may be against the heat rollers. Unweb
and reload the film properly.