Electrical Installation - AEG 47132MM-MN User Manual

Dual fuel cooker
Hide thumbs Also See for 47132MM-MN:
Table of Contents

Advertisement

28
www.aeg.com
1. Connect the pressure gauge to the
Rapid injector.
2. Examine the supply pressure by
turning the Rapid burner and one
other burner fully on, and lighting
them. The pressure must be:
a) 20 mbar for Natural Gas
b) 29 mbar for LPG, butane only
c) 37 mbar for LPG, propane only.
3. Turn the taps off and disconnect the
pressure gauge.
4. Make sure that all burners work
correctly.
13.8 Checking the hob burners
1. Lift the lid.
2. Put on the burner crowns and caps.
Make sure that they are correctly
seated.
3. Put on the pan supports.
4. Light one of the hob burners.
To light the hob burner refer to the
"Ignition of the hob burners".
Check if the flame is regular.
Check each of the burners.
5. Turn the knob for the hob to the off
position.
13.9 Checking the Lid Safety
Device
1. Lift the lid.
2. Light one of the hob burners.
To light the hob burner refer to the
"Ignition of the hob burners".
3. Close the lid. There should be no gas
supply to the hob burners. The
burner goes out.
4. Turn the knob to the off position and
lift the lid. The gas supply should be
restored to the hob burners, when
you turn the knob on.

13.10 Electrical installation

WARNING!
The manufacturer is not
responsible if you do not
follow the safety precautions
from Safety chapters.
This appliance is supplied without a main
plug or a main cable.
Applicable types of cables for different
phases:
Phase
1
3 with neutral
WARNING!
The power cable must not
touch the part of the
appliance shaded in the
illustration.
13.11 Covering terminal board
• The recommended cross-section area
is six square millimetres (6 mm²).
• When you refit the mains terminal
cover, make sure that the lower tabs
are located inside the bottom edge of
the aperture, before you fix the two
screws into the top edge of the mains
terminal cover.
• Make sure that the cover is securely
fastened.
To open the cover of
terminal board obey the
procedure in opposite
sequence.
Min. size cable
3x2.5 mm²
5x1.0 mm²

Advertisement