30
www.aeg.com
12.2 Service data
If you cannot find a solution to the
problem yourself, contact your dealer or
an Authorised Service Centre.
The necessary data for the service centre
is on the rating plate. The rating plate is
We recommend that you write the data here:
Model (MOD.)
Product number (PNC)
Serial number (S.N.)

13. INSTALLATION

WARNING!
Refer to Safety chapters.
13.1 Technical data
Dimensions
Height
Width
Depth
13.2 Location of the appliance
You can install your freestanding
appliance with cabinets on one or two
sides and in the corner.
Minimum distances
Dimension
A
894 - 912 mm
600 mm
609 mm
A
mm
685
on the front frame of the oven cavity. Do
not remove the rating plate from the
oven cavity.
.........................................
.........................................
.........................................
13.3 Levelling of the appliance
Use small feet on the bottom of
appliance to set the appliance top
surface level with other surfaces.
13.4 Electrical installation
WARNING!
The manufacturer is not
responsible if you do not
follow the safety precautions
from Safety chapters.
This appliance is supplied without a main
plug or a main cable.
Applicable types of cables for different
phases:
Phase
1
3 with neutral
Min. size cable
3x6.0 mm²
5x1.5 mm²