Category
E1 Port Property
E1 Port Property Copy
You can copy one or all of the following setting values from one port to other ports by clicking the
on the E1 Port Property screen and configuring the E1 Port Property Copy screen.
•
Channel Type
•
CO Dial Mode
•
E1 Receiver Type
Setting Item
Group-B Code
Assignment—
Unallocated
Group-B Code
Assignment—
Congestion
Group-B Code
Assignment—
Out-of-Service
Group-B Code
Assignment—No Billing
Group-B Code
Assignment—Collect
Call Reject
CH
Connection
Channel Type
CO Dial Mode
E1 Receiver Type
Receive Digits
CPC Detection
Time-Out
CPC Detection Time-In
DTMF Width
Ringback Tone to
Outside Caller
Answer Wait Timer
(*60s)
Pause Time
Flash Time
Disconnect Time
Value Range
Undefined, 1–15
Undefined, 1–15
Undefined, 1–15
Undefined, 1–15
Undefined, 1–15
1–30
INS, OUS, Fault
Undefined, DR2
DTMF, MFC-R2
DTMF, MFC-R2,
Undefined
0–15
None, 80 × n (n=2–75)
ms
None, 80 × n (n=2–75)
ms
80 ms, 160 ms
Disable, Enable
None, 1–4
1.5 s, 2.5 s, 3.5 s, 4.5 s
None, 16 × n (n=1–255)
ms
0.5 s, 1.5 s, 2.0 s, 4.0 s,
12.0 s
4.4.2 Setting List
Default Value
3
4
4
Undefined
Undefined
–
–
Undefined
DTMF
Undefined
3
160 ms
80 ms
80 ms
Enable
None
1.5 s
608 ms
1.5 s
button
Installation Manual
47