Chapter 2: Infrastructure Device Installation
category, and therefore must be treated with greater considerations as far as grounding requirements
are concerned.
Since Type B grounding requirements stipulate 5 ohms or less impedance to earth ground, things such
as soil pH, type of grounding rods, size of conductors, and ground enhancing materials must be taken
into account to achieve this goal. To verify the impedance requirements are met, a special
Earth/Ground Resistance Tester (megohmmeter) may be necessary.
To avoid damage to the equipment, adequate grounding for all MOTOMESH Duo
4300 devices is mandatory.

Assembling AC and DC Power

Use the following procedures to assemble a MOTOMESH Duo 4300 Device with AC or DC power.
Additional AC power cable

US AC Power Assembly

Procedure 2-4 Assembling a US AC Power

Place the brackets at the desired position on the pole.
1
Adjust the position of the box so that the antenna connectors are positioned vertically. Align the antennas
2
with the N-type connectors on the box and rotate to close.
Insert the cable into the external Ethernet port and tighten the connector to ensure a weatherproof seal.
3
Insert the Power Plug into the 4-pin connector.
4

European and Australian AC Power Assembly

Procedure 2-5 Assembling a European or Australian AC Power

1
Place the brackets at the desired position on the pole.
2
Adjust the position of the box so that the antenna connectors are positioned vertically. Align the antennas
with the N-type connectors on the box and rotate to close.
Insert the cable into the external Ethernet port and tighten the connector to ensure a weatherproof seal.
3
Insert the Power Plug into the 3-pin connector.
4
May 2008
If the MOTOMESH Duo 4300 Device product is attached to a light arm and the
attachment point meets the Type B grounding requirements, then the grounding stud
attachment point is not required to be used.
Wiring Instructions
are detailed in Chapter 3 of this users guide.