If problems persist after you have followed the Recommended
Actions, contact ADTRAN Technical Support at (800) 726-8663.
"T
"
EST
LIGHT IS LIT OR BLINKING
The test alarm will remain on (solid) during power-up, indicating
a self-test is in progress. The light will flash or remain on (solid) if
the self-test fails.
P
OSSIBLE
• One-flash interval indicates a RAM test failure. ............................... 1
• Two-flash interval indicates the T1-C mux failed
internal test. ....................................................................................... 1
• Three-flash interval indicates the T1-A framer failed. ...................... 1
• Four-flash interval indicates the T1-B framer failed. ........................ 1
• Five-flash interval indicates a DSP failure. ........................................ 1
• On (solid) indicates a faulty internal component. ............................ 1
R
ECOMMENDED
Replace the BBP or the RFC.
1.
"TST"
LIGHT IS LIT AFTER PRESSING
The Remote Test light will activate during a remote test in progress.
The Remote Test performs a 10-second bit error rate test (BERT)
over the RF link to the far-end.
P
OSSIBLE
• A Remote Test has been activated from the front
panel "Remote Test" button or the VT-100 user
interface. ............................................................................................. 1
R
ECOMMENDED
1.
Allow the remote test to complete. If the Remote Test Fail light does
not activate, the remote test passed. If the Remote Test Fail light
activates, see section on FAIL light is lit after pressing Remote Test
button.
I M P O R T A N T
C
AUSE
A
:
CTIONS
C
AUSE
A
:
CTIONS
R
"R
T
"
EMOTE
EST
BUTTON
R
61280.003L1-1B
A
ECOMMENDED
CTION
(
)
SEE LIST BELOW
A
ECOMMENDED
CTION
(
)
SEE LIST BELOW