The menu selections are described below.
T1A and T1B Framing allow each T1 to be configured for SF or
T1A and T1B Line Code allow each T1 to be configured for AMI or
T1A and T1B Line Buildout allow each T1 to be configured for the
It is possible for the spreading code to be changed remotely through
the VT-100 interface from the other end of the link. When this is
performed, communications will be lost to the far end. The
spreading code will change to code "0" and communications will
be lost as soon as this change is made. If this happens, set the
Spreading Code on the local unit to code "0." The units should
regain communications as soon as the correct code is selected.
Set Chipping Code allows the chipping code to be selected. Each
Set Tx Power allows the transmitter power to be adjusted.
Set Freq Plan allows the frequency plan to be set to A or B. One
Reset All Statistics resets all the error counters.
Enable/Disable Password allows password protection to be enabled
Change Password allows the password to be set.
Site ID allows a string of up to 32 characters to be entered as a site
ESF framing.
B8ZS.
appropriate line buildout, based on the distance to the T1
equipment.
end of the link must be configured for the same chipping code.
end of a link must be set to A and the other set to B. The
setting of the BBP must match the attached RFC. For further
information, see "Setting the RFC Frequency Plan" in the
"Installation" chapter of this manual.
or disabled. The default setting is Disabled.
identifier.