Alarm Page; Test Menu - ADTRAN TRACER User Manual

Hide thumbs Also See for TRACER:
Table of Contents

Advertisement

P
36
AGE
S
3
ECTION
A
P
LARM
AGE
This screen presents alarm information for the system. The T1A
or T1B alarms are described in the chapter entitled
"Troubleshooting." If any of the T1A or T1B alarms are active, a
minor alarm will be indicated at the alarm contacts. The RF link
alarm will be activated when communication between the BBP
and the RFC has failed. Code Sync, Carrier Sync, and T1 Mux
Framer alarms indicate that various portions of the spread
spectrum data pump are not operating. Any of these alarms will
cause a major alarm to be activated at the alarm contacts.
Code Sync Alarm
Carrier Sync Alarm
T1Mux Framer Alarm
RX LOS (Red) Alarm
RX AIS (Blue) Alarm
RX Yellow Alarm
BPV Alarm
TX AIS (Blue) Alarm
=====================================================================
Press 'm' for Main Menu:
T
M
EST
ENU
This screen allows each T1 to be put into loopback mode.
1) Local T1A Line Loopback
2) Local T1B Line Loopback
3) Local T1A Link Loopback
4) Local T1B Link Loopback
5) Remote T1A Link Loopback
6) Remote T1B Link Loopback
=====================================================================
Press 'm' for Main Menu:
TRACER Alarm Page
Site: Adtran
Off
Off
Off
T1A
Off
Off
Off
Off
Off
TRACER Test Menu
Site: Adtran
61280.003L1-1B
T1B
Off
Off
Off
Off
Off
Figure 3-6. Alarm Page
Figure 3-7. Test Menu