Storage; Maintenance; Service - Master TB116 Owner's Manual

Propane tent event forced air heater
Hide thumbs Also See for TB116:
Table of Contents

Advertisement

Available languages

Available languages

CAUTION: Disconnect heater
from propane supply tank(s).
1.. Store.propane.tank(s).in.safe.manner..See.
Chapter. 5. of. Standard for Storage and
Handling of Liquefied Petroleum Gases,
ANSI/NFPA 58.and.the.Natural Gas and
Propane Installation Code CSA B149.1..
Follow.all.local.codes..Always.store.pro-
pane.tanks.outdoors.
WARNINGS
• Never service heater while it
is plugged in, connected to
propane supply, operating, or
hot. Severe burns and electri-
cal shock can occur.
• Keep heater clear and free
from combustible materials,
gasoline, and other flammable
vapors and liquids.
• Do not block the flow of com-
bustion or ventilation air.
1. Keep heater clean. Clean heater annually
or.as.needed.to.remove.dust.and.debris..If.
heater.is.dirty.or.dusty,.clean.heater.with.
a.damp.cloth..Use.household.cleaners.on.
difficult spots.
WARNING: Never service
heater while it is plugged in,
connected to propane supply,
operating, or hot. Severe burns
and electrical shock can occur.
12

STorage

2. Place plastic cover caps over brass fittings
3.. Store.in.dry,.clean,.and.safe.place.
4.. When.taking.heater.out.of.storage,.always.

MainTenance

2.. Inspect. heater. before. each. use.. Check.
3.. Inspect. hose/regulator. assembly. before.
4.. Have.heater.inspected.yearly.by.a.quali-
5. Keep inside of heater free from combus-
burner
Check.burner.air.inlet.after.every.300.hours.
of.operation.to.ensure.burner.air.inlet.is.free.
of.dust.or.debris..Use.compressed.air.(30.PSI.
or.less).to.clean.out.burner.air.inlet.

Service

IMPORTANT: CHECK FOR GAS LEAKS..Test.
all.gas.piping.and.connections.for.leaks.after.
installation.or.servicing..Never.use.an.open.
flame to check for a leak. Apply a noncorrosive
leak detection fluid to all joints (available at lo-
cal plumbing supply stores). Bubbles forming
show.a.leak..Correct.all.leaks.at.once.
www.desatech.com
on.inlet.connector.and.hose/regulator.as-
sembly..
check.inside.of.heater..Insects.and.small.
animals. may. place. foreign. objects. in.
heater. Keep inside of heater free from
combustible.and.foreign.objects.
connections. for. leaks..Apply. a. noncor-
rosive leak detection fluid to connections.
Bubbles forming show a leak. Correct all
leaks.at.once.
each. use.. If. hose. is. highly. worn. or. cut,.
replace with one specified by manufac-
turer.
fied service agency.
tible.and.foreign.objects..Remove.motor.
and.other.internal.parts.if.needed.to.clean.
inside.of.heater.(see.Service,.below).