Specifications - Master TB116 Owner's Manual

Propane tent event forced air heater
Hide thumbs Also See for TB116:
Table of Contents

Advertisement

Available languages

Available languages

Thermal.
Limit.Switch
Pressure.
Switch
Pressure
Vacuum
Injector
• Output Rating - 125,000 Btu/Hr (131,882 kJ/Hr)
•. Fuel.Consumption.-.1.4.Gal/Hr.(5.2.Liters/Hr),.5.8.lb/Hr.(2.6.kg/Hr)
•. Propane.Vapor.Fuel.Only
•. Manifold.Pressure.-.10".(25.4.cm).WC
•. Supply.Pressure.To.Regulator:.Minimum.(for.purposes.of.input.adjustment).10.psi.(69.kPa),.
Maximum.-.Tank.Pressure
•. Regulator.Outlet.Pressure.-.11".wc
• Electric Input - 120 V/60 Hz
•. Amperage.-.Start.7,.Run.3.5
•. Load.-.10.amps.on.receptacle
•. Hot.Air.Output.(Approx).-.1000.CFM.(28.3.m
•. Motor.-.1,100.RPM,.1/4.HP
• Ignition - Electronic Direct Spark Ignition (D.S.I.)
•. Ignitor.Gap.-.0.12"/0.15".(3.1/3.8.mm)
16
Service
Continued
Burner
Figure 15 - Tent Heater Parts

SPeciFicaTionS

/min)
3
www.desatech.com
Switches
Thermostat
Terminal.
Boards
DSI
Receptacle
Solenoid.
Valve
Pressure.
Tap
Gas.Line
120193-01A