Lldp Timer Tx-Delay; Lldp Timer Tx-Interval - HP A5830 Series Command Reference Manual

Layer 2 - lan switching
Hide thumbs Also See for A5830 Series:
Table of Contents

Advertisement

Example
# Set the LLDP re-initialization delay to 4 seconds.
<Sysname> system-view
[Sysname] lldp timer reinit-delay 4

lldp timer tx-delay

Description
Use the lldp timer tx-delay command to set the LLDPDU transmit delay.
Use the undo lldp timer tx-delay command to restore the default.
By default, the LLDPDU transmit delay is 2 seconds.
It is a good practice to set the LLDPDU transmit delay to be no greater than a quarter of the LLDPDU
transmit interval.
If the LLDPDU transmit delay is greater than the LLDPDU transmit interval, the device uses the LLDPDUs
transmit delay as the transmit interval.
Related commands: lldp timer tx-interval.
Syntax
lldp timer tx-delay delay
undo lldp timer tx-delay
View
System view
Default level
2: System level
Parameter
delay: Sets the LLDPDU transmit delay, ranging from 1 to 8192 seconds.
Example
# Set the LLDPDU transmit delay to 4 seconds.
<Sysname> system-view
[Sysname] lldp timer tx-delay 4

lldp timer tx-interval

Description
Use the lldp timer tx-interval command to set the LLDPDU transmit interval.
Use the undo lldp timer tx-interval command to restore the default.
By default, the LLDPDU transmit interval is 30 seconds.
It is a good practice to set the LLDPDU transmit interval to be no less than four times the LLDPDU transmit
delay.