Cisco Nexus 6000 Series Configuration Manual page 73

Hide thumbs Also See for Nexus 6000 Series:
Table of Contents

Advertisement

Configuring FCoE NPV
last clearing of "show interface" counters Tue May 31 20:56:41 2011
Interface last changed at Wed Jun
This example shows the information about the vFC 1 interface including attributes and status:
switch# show interface vfc 1
vfc1 is trunking (Not all VSANs UP on the trunk)
Bound interface is Ethernet1/19
Hardware is Virtual Fibre Channel
Port WWN is 20:00:00:05:9b:74:bd:bf
Admin port mode is F, trunk mode is on
snmp link state traps are enabled
Port mode is TF
Port vsan is 20
Trunk vsans (admin allowed and active) (1,20,100,200,300,400,500)
Trunk vsans (up)
Trunk vsans (isolated)
Trunk vsans (initializing)
1 minute input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
1 minute output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
last clearing of "show interface" counters Tue May 31 20:56:41 2011
Interface last changed at Wed Jun
This example shows the information about the NPV FLOGI session:
switch# show npv flogi-table
--------------------------------------------------------------------------------
SERVER
INTERFACE VSAN FCID
--------------------------------------------------------------------------------
vfc1
Total number of flogi = 1.
This example shows the status of the NPV configuration including information about VNP ports:
switch# show npv status
npiv is enabled
disruptive load balancing is disabled
External Interfaces:
====================
Interface:
Interface:
Interface: vfc90,
Interface: vfc100, State: Down
Interface: vfc110, State: Down
Interface: vfc111, State: Down
OL-27932-01
0 discards, 0 errors
7 frames output, 1004 bytes
0 discards, 0 errors
355278397 frames input, 573433988904 bytes
0 discards, 0 errors
391579316 frames output, 572319570200 bytes
0 discards, 0 errors
20
0x670000 21:01:00:1b:32:2a:e5:b8 20:01:00:1b:32:2a:e5:b8 vfc26
vfc25, State: Trunking
VSAN:
1, State: Up
VSAN:
200, State: Up
VSAN:
400, State: Up
VSAN:
20, State: Up
VSAN:
100, State: Up
VSAN:
300, State: Up
VSAN:
500, State: Up, FCID: 0xa10000
vfc26, State: Trunking
VSAN:
1, State: Up
VSAN:
200, State: Up
VSAN:
400, State: Up
VSAN:
20, State: Up
VSAN:
100, State: Up
VSAN:
300, State: Up
VSAN:
500, State: Up, FCID: 0xa10001
State: Down
Cisco Nexus 6000 Series NX-OS SAN Switching Configuration Guide, Release 6.x
1 21:53:08 2011
(20)
()
(1,100,200,300,400,500)
1 20:25:36 2011
PORT NAME
Configuration Examples for FCoE NPV
EXTERNAL
NODE NAME
INTERFACE