Mapping Requirements - Cisco Nexus 6000 Series Configuration Manual

Hide thumbs Also See for Nexus 6000 Series:
Table of Contents

Advertisement

Configuring FCoE NPV

Mapping Requirements

hosts evenly across the available FCF uplink ports. An FCoE NPV bridge is VSAN-aware and capable of
assigning VSANs to the hosts.
Figure 4: FCoE NPV Model

Mapping Requirements

VSANs and VLAN-VSAN Mapping
VSANs from the hosts must be created and for each VSAN, a dedicated VLAN must also be created and
mapped. The mapped VLAN is used to carry FIP and FCoE traffic for the corresponding VSAN. The
VLAN-VSAN mapping must be configured consistently in the entire fabric. The Cisco Nexus device supports
32 VSANs.
FC Mapping
The FC-MAP value associated with a SAN fabric must be configured on the FCoE NPV bridge which helps
the FCoE NPV bridge isolate misconnections to FCFs in other fabrics.
Cisco Nexus 6000 Series NX-OS SAN Switching Configuration Guide, Release 6.x