Mitsubishi Electric CC-Link IE Basic Reference Manual page 41

Field network
Hide thumbs Also See for CC-Link IE:
Table of Contents

Advertisement

■Link Scan Setting
Set timeout time and number of retries for slave station disconnection detection.
Window
Displayed items
Item
Slave Station Disconnect
Time-out Period (10 to
Detected Setting
65535)
Counts
Slave Station Disconnect
Detected Image Diagram
Display
*1 Setting range of MELSEC iQ-F is 20 to 65535.
*2 Timeout time and the number of times for disconnection detection are counted for each slave station.
*3 Disconnection occurs in the event that no response is received from the slave station for the specified number of times in succession
within the timeout time.
*4 In GX Works3 with version earlier than "1.035M" or GX Works2 with version earlier than "1.565P", the default value is 500.
• For setting of timeout time, specify an adequate value according to the actual system used. ( Page 24
No response received from a slave station)
• Time-out Period and Counts can be set for each group.
Description
Set the timeout time (ms) for slave station disconnection
*2
detection.
( Page 23 Data flow of cyclic
transmission)
Set the number of retries for slave station disconnection
*2*3
detection.
The operation image regarding the slave station
disconnection detection period is displayed. Refer to this
at the setting of "Time-out Period".
8.1 Settings for the Master Station in MELSEC iQ-R/MELSEC iQ-F
Setting
Default
range
*1
*4
10 to 65535
100
3, 5, 10
3
8 PARAMETER SETTINGS
8
39