Configuring Netflow On Copp Interface Support - Cisco Nexus 7000 Series Configuration Manual

Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

Configuring Netflow on CoPP Interface Support

Step 6
Step 7
Configuring Netflow on CoPP Interface Support
You can create a flow record and add keys to match on and nonkey fields to collect in the flow.
Before You Begin
Perform the following configuration on the default VDC.
Procedure
Step 1
Enter global configuration mode:
switch# configure terminal
Step 2
Enter control-plane configuration mode. Enable users to associate attributes that are associated with the control
plane of the device:
switch(config)# control-plane
Step 3
Associate an IPv4 flow monitor and a sampler to the control-plane for output packets. You can enter up to 63
alphanumeric characters for the flow monitor name and the sampler name:
switch(config-cp)# ip flow monitor name output sampler name
What to Do Next
You must perform the following tasks to complete configuring Netflow on COPP Interface Support feature:
Creating a Flow Record, on page 376
Creating a Flow Monitor
Creating a Sampler, on page 382
Cisco Nexus 7000 Series NX-OS System Management Configuration Guide
384
Command or Action
Example:
switch(config-if)# layer2-switched
flow monitor testmonitorl2 input
sampler testsamplerl2
exit
Example:
switch(config-if)# exit
copy running-config startup-config
Example:
switch(config)# copy running-config
startup-config
Purpose
enter up to 63 alphanumeric characters for the flow
monitor name and the sampler name.
Returns to global configuration mode.
(Optional)
Saves the change persistently through reboots and
restarts by copying the running configuration to the
startup configuration.
Configuring NetFlow