Ny-Series Instructions Reference Manual (W560 - Omron NY532-5400 Reference Manual

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

2 Instruction Descriptions
 Interruption executed (when Busy is TRUE)
The operation is as follows if Abort is changed to TRUE while Busy is TRUE.
TRUE
Execute
FALSE
TRUE
Abort
FALSE
TRUE
Busy
FALSE
TRUE
Done
FALSE
TRUE
Error
FALSE
Command
TRUE
Aborted
FALSE
ErrorID
ErrorIDEx
*1 Interruption processing
*2 Changes to FALSE after one task period.
 Interruption executed (when Execute is TRUE)
The operation is as follows if both Abort and Execute are changed to TRUE.
TRUE
Execute
FALSE
TRUE
Abort
FALSE
TRUE
Busy
FALSE
TRUE
Done
FALSE
TRUE
Error
FALSE
Command
TRUE
Aborted
FALSE
ErrorID
ErrorIDEx
*1 Changes to FALSE after one task period.
2-1210
*1
*2
Cleared to 0.
Cleared to 0.
*1
Cleared to 0.
Cleared to 0.