Jumper Assignment And Codings; Assignment Of Plug-In Jumper On Circuit Board Vr20; External Switching Of The Heating Program; External Heat Demand - Viessmann VITODENS 200 Start-Up And Service Instructions

Wb2 series wall-mounted, gas-fired condensing boiler
Hide thumbs Also See for VITODENS 200:
Table of Contents

Advertisement

Jumper Assignment and Codings

Assignment of plug-in jumper on circuit board VR20

External switching of the heating program (telephone contact)

External heat demand

With programming unit
Change coding address "011:000" to
"011:001".
With programming unit
Change coding address "011:000" to
"011:001" and "027:000" to
"027:001".
Additional Information
Plug-in jumper "X6"
Factory default setting without
"External burner disable" function.
With "External burner disable"
function.
Plug-in jumpers "X2"-"X4"
Factory default setting without
Viessmann 2-wire BUS expansion
module: Two plug-in jumpers connected
as shown.
With Viessmann 2-wire BUS expansion
module: Both plug-in jumpers removed.
field supplied
Boiler start-up takes place in
accordance with the settings of
coding address "0C5".
Boiler water temperature is
maintained at the value selected in
coding address "0A2".
59