Viessmann VITODENS 200 Start-Up And Service Instructions page 55

Wb2 series wall-mounted, gas-fired condensing boiler
Hide thumbs Also See for VITODENS 200:
Table of Contents

Advertisement

Control Unit for Weather-Responsive Operation
Overview of coding addresses (continued)
Coding (factory
Function mode
default setting)
Address: Value
0A4:255
Do not change
0A5:255
Do not change
0A6:255
Do not change
0A7:060
DHW
tank
0A8:000
Boiler
Possible coding changes for coding address 0A8 "external disable"
Coding
Heating circuit
pump
0A8:000
×
0A8:001
OFF
0A8:002
×
0A8:003
×
0A8:004
OFF
0A8:005
OFF
0A8:006
OFF
0A8:007
OFF
× = in normal control mode
Setpoint value for "Additional
function for domestic hot
water heating"
("Anti-Legionnaire-Function"
– domestic hot water heated
briefly to 140 ºF/60 ºC)
See table below for effect of
external disable signal
(also see page 59)
Heating circuit with mixing valve
(extension kit)
Heating circuit pump
×
OFF
×
OFF
×
×
×
OFF
with programming unit
(continued)
Coding
Possible changes
change
Address: Value
A07:061
Setting range between 142 to 158 ºF/
to
61 and 70 ºC.
A07:070
IMPORTANT
Do not adjust domestic hot water
temperature more than 158 ºF/
70 ºC.
0A8:001
See table below for effect of external disable
to
signal
0A8:007
Tank
(Circulating pump
f
for tank heating)
Mixing valve
×
×
CLOSED
OFF
×
OFF
CLOSED
×
×
×
×
OFF
×
×
CLOSED
×
Additional Information
Burner
g
k h
i
)
Blocked
Blocked
Blocked
Blocked
Blocked
Blocked
Blocked
Blocked
55