3.6
M+FX5CCLIEF_StationNoSet
Name
M+FX5CCLIEF_StationNoSet
Overview
Item
Description
Overview
Sets the station number for the own station.
Symbol
(1)
(2)
(3)
Labels
■Input label
No.
Variable name
Name
(1)
i_bEN
Execution command
(2)
i_stModule
Module label
(3)
i_uSetStationNo
Setting station
number
■Output label
No.
Variable name
Name
(4)
o_bENO
Execution status
(5)
o_bOK
Normal completion
(6)
o_bErr
Error completion
(7)
o_uErrId
Error code
M+FX5CCLIEF_StationNoSet
B
:
i_bEN
DUT
:
i_stModule
UW
:
i_uSetStationNo
Data type
Bit
Structure
Word [unsigned]
Data type
Bit
Bit
Bit
Word [unsigned]
o_bENO
:
B
(4)
o_bOK
:
B
(5)
o_bErr
:
B
(6)
o_uErrId
:
UW
(7)
Range
Description
ON, OFF
ON: The FB is activated.
OFF: The FB is not activated.
The setting range
Specify the module label of the FX5-CCLIEF.
differs depending on
the module label.
1 to 120
Specifies the station number to be set.
Default value
Description
OFF
ON: The execution command is ON.
OFF: The execution command is OFF.
OFF
When this label is ON, it indicates that the station
number has been set correctly.
OFF
When this label is ON, it indicates that an error has
occurred in the FB.
0
Stores the error code that occurred in the FB.
3 CC-LINK IE FIELD NETWORK MODULE FB
3.6 M+FX5CCLIEF_StationNoSet
3
43