M+Fx5Ucpu-En_Slmp_Devicewrite_Ip - Mitsubishi Electric MELSEC iQ-F Reference

Fx5 ethernet/cc-link ie function block
Hide thumbs Also See for MELSEC iQ-F:
Table of Contents

Advertisement

■Output label
No.
Variable name
Name
(11)
o_bENO
Execution status
(12)
o_bOK
Normal completion
(13)
o_bErr
Error completion
(14)
o_uErrId
Error code
■Public label
No.
Variable name
(15)
pbi_uRequestModuleIO
(16)
pbi_uResendCountMax
(17)
pbi_uMonitorTime
(18)
pbo_uResendCount
(19)
pbo_u4ErrTime
(20)
pbo_u2ErrIP_Address
Data type
Bit
Bit
Bit
Word [Unsigned]/Bit
String [16-bit]
Name
Data type
Requested module I/
Word [Unsigned]/Bit
O No.
String [16-bit]
Maximum number of
Word [Unsigned]/Bit
resends
String [16-bit]
Arrival monitoring
Word [Unsigned]/Bit
time
String [16-bit]
Number of resends
Word [Unsigned]/Bit
String [16-bit]
Error occurrence time
Word [Unsigned]/Bit
String [16-bit] (0..3)
Error-detected station
Word [Unsigned]/Bit
IP address
String [16-bit] (0..1)
Default value
Description
OFF
ON: The execution command is ON.
OFF: The execution command is OFF.
OFF
Device writing has been completed normally when this
output is on.
OFF
When this label is ON, it indicates that an error has
occurred in the FB.
0
Stores the error code that occurred in the FB.
Range
Description
03FFH, 03E0H
Specify the module of the access destination.
to 03E3H,
• 03FFH: Own station, control CPU
03D0H to
• 03E0H: Multiple CPU No.1
03D3H
• 03E1H: Multiple CPU No.2
• 03E2H: Multiple CPU No.3
• 03E3H: Multiple CPU No.4
• 03D0H: To control system CPU
• 03D1H: To standby CPU
• 03D2H: To system A CPU
• 03D3H: To system B CPU
0 to 15
Specify the number of resends to be performed if the
data transfer is not completed within the monitoring
time specified by "arrival monitoring time".
• 0 to 15
0, 1 to 32767
Specify the monitoring time until completion of
processing. If the processing is not completed within
the monitoring time, data is resent until the value
specified in "maximum number of resends" is reached.
• 0: 10 s
• 1 to 32767: 1 to 32767 s
The number of resends performed (result) is stored.
Clock data at the time of error occurrence is stored.
1st word
• Upper 8 bits: Month (01H to 12H)
• Lower 8 bits: Lower 2 digits of year (00H to 99H)
2nd word
• Upper 8 bits: Hour (00H to 23H)
• Lower 8 bits: Day (01H to 31H)
3rd word
• Upper 8 bits: Second (00H to 59H)
• Lower 8 bits: Minute (00H to 59H)
4th word
• Upper 8 bits: Upper 2 digits of year (00H to 99H)
• Lower 8 bits: Day of week (00H (Sunday) to 06H
(Saturday))
The IP address of the station in which an error was
detected is stored. The third and fourth octets are
stored in the 1st word, and first and second octets are
stored in the 2nd word.
b15
1st word
2nd word

2.6 M+FX5UCPU-EN_SLMP_DeviceWrite_IP

b8
b7
b0
Third octet
Fourth octet
First octet
Second octet
2 FX5 ETHERNET FB
2
21