Mounting Frames For Pt Power Modules - Siemens SINAMICS PM240-2 Hardware Installation Manual

Power module for sinamics g120
Hide thumbs Also See for SINAMICS PM240-2:
Table of Contents

Advertisement

9.2

Mounting frames for PT power modules

Order numbers for mounting frames
● FSA: 6SL3260-6AA00-0DA0
● FSB: 6SL3260-6AB00-0DA0
● FSC: 6SL3260-6AC00-0DA0
All of the necessary nuts and seals are included in the scope of delivery.
Mounting instructions for the mounting frames
Procedure
Proceed as follows to correctly mount the Power Module:
1. Prepare a cutout and holes in the control cabinet panel for the mounting frame
corresponding to the dimension drawing.
2. Insert the mounting frame from the rear of the control cabinet through the corresponding
holes and fix it in place at the fixing screws for the control cabinet panel; tighten the two
nuts by hand.
3. Attach the seal to the inner side of the control cabinet.
4. Insert the Power Module and tighten the screws by hand.
5. Finally, tighten the eight or ten screws with a torque of 3.5 Nm.
You have correctly installed the Power Module.
Power Module PM240-2
Hardware Installation Manual, 01/2017, A5E33294624B AE
9.2 Mounting frames for PT power modules
Accessories
107

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents