Leds After Over-The-Air Reprogramming - Honeywell CNI2 Operating And Installation Manual

Cellular network interface - 2 mercury instruments
Table of Contents

Advertisement

CODE
61
Not used
62
Not used
63
Not used
64
Not used
65
Not used
66
Not used
67
Not used
68
Not used
69
Not used
71
Configuration memory has not been programmed or is corrupt. Attempt to
reload the configuration. This could be caused by a nearly-depleted battery.
Otherwise the FLASH memory in the processor is defective.
72
There is a data retention or communications problem with the non-volatile
EEPROM memory device.
73
Could not write into FLASH memory. This is a problem with the processor.
74
Over-the-air firmware download was aborted. This is usually a network-
related problem or problems with the the data collection system data
collection system.
75
The watchdog timer expired and generated a reset. This could be caused
by defective firmware but might also be caused by a defective crystal.
76
Not used
77
Not used
78
Not used
79
Not used

LEDS AFTER OVER-THE-AIR REPROGRAMMING

If a new operating program ("firmware") is successfully downloaded over-the-air the call will
complete as normal. Then the LEDs will rapidly flash in an alternating pattern for anywhere
between 10 – 30 seconds as the CNI2 reprograms itself. At the end of the operation the CNI2
will return to "sleep" mode and both LEDs will turn off.
CNI2 Operating and Installation Guide
DESCRIPTION
LED Error Codes 61 thru 79
107