OVER-THE-AIR (OTA) PROGRAMMING

What is Over-the-Air Programming?

The CNI2's configuration and/or its operating program (called "firmware") can be changed once
the unit is installed in the field. This is called over-the-air (OTA) programming. At the present
®
time this feature is only supported when using the DC-2009
data collection system and then
®
®
only in Internet (IP) mode. MV90
does not support OTA changes and DC-2009
does not
support OTA in CSD mode.
NOTE
The remote unit ID (RUID) and Service Type (GSM or CDMA) cannot be changed
over-the-air. These can only be changed using a programming cable.
WARNING
In some case and in some countries (Canada for example) a metering device is not allowed
to have its program or configuration changed over-the-air.

Over-the-Air Configuration Changes

IMPORTANT
It is extremely important that all configuration parameters be correct, especially those
related to the cellular network.
Otherwise the CNI2 may not be able to contact the central office again.
This will require an on-site visit to correct the problem.
®
®
Both MP32
and DC-2009
must be running on the same system at the same time. The
PROGRAM ACCOUNTS / LISTS button on the bottom of the main MP32 screen will be enabled
only when both programs are running.
Set up all configuration items as you would for any CNI2. Then select the PROGRAM
ACCOUNTS / LISTS button on the bottom of the main MP32 screen. The following screen will
appear.