CODE
41
TCP/IP variables could not be initialized. This is generally a firmware
problem.
42
Could not establish a point-to-point (PPP) connection with network. This
might be caused by the cellular account not being setup for Internet service.
It could also be caused by an incorrect PAP username or password, or an
incorrect APN for GSM service.
43
Could not establish a TCP/IP connection to the destination server. This
might be caused by the cellular account not being setup for Internet service.
It could also be caused by an incorrect PAP username or password.
44
Error sending data to the destination server. This is usually caused by an
unexpected termination of a connection due to network problems or poor
signal conditions.
45
Error receiving data from the destination server. This is usually caused by
an unexpected termination of a connection due to network problems or poor
signal conditions.
46
Unexpected command from the data collection system. This might indicate
a problem with the way the CNI2 is setup in the data collection system.
47
Not used
48
Not used
49
Not used
51
Unexpected response from the data collection system. This might indicate a
problem with the way the CNI2 is setup in the data collection system.
52
The memory address specified in a memory write command from the host
system (the data collection system) is illegal. This might indicate a problem
with the way the CNI2 is setup in the data collection system.
53
Unexpected message received from the data collection system to terminate
the connection. This can be caused by network problems or poor signal
conditions.
54
Message from the data collection system was too large. This might indicate
a problem with the way the CNI2 is setup in the data collection system.
55
Over-the-air configuration update command contained a memory address
outside of the configuration memory area.
56
Unrecognized command from the data collection system or an inappropriate
combination of commands was received. This might indicate a problem with
the way the CNI2 is setup in the data collection system.
57
Not used.
58
Message from the data collection system had an incorrect CRC value. This
is usually caused by an unexpected termination of a connection due to
network problems or poor signal conditions.
59
Not used
DESCRIPTION

LED Error Codes 41 thru 59