TCP/UDP Source No.
TCP/UDP Source
Range
TCP/UDP Destination
Filter
TCP/UDP Destination
Number
 TCP/UDP Destination
Range
 TCP FIN
 TCP SYN
Any: No TCP/UDP source filter is specified (TCP/UDP source filter status
is "don't-care").
Specific: If you want to filter a specific TCP/UDP source filter with this
ACE, you can enter a specific TCP/UDP source value. A field for entering a
TCP/UDP source value appears.
Range: If you want to filter a specific TCP/UDP source range filter with this
ACE, you can enter a specific TCP/UDP source range value. A field for
entering a TCP/UDP source value appears.
When "Specific" is selected for the TCP/UDP source filter, you can enter a
specific TCP/UDP source value. The allowed range is 0 to 65535. A frame that
hits this ACE matches this TCP/UDP source value.
When "Range" is selected for the TCP/UDP source filter, you can enter a specific
TCP/UDP source range value. The allowed range is 0 to 65535. A frame that hits
this ACE matches this TCP/UDP source value.
Specify the TCP/UDP destination filter for this ACE.
Any: No TCP/UDP destination filter is specified (TCP/UDP destination filter
status is "don't-care").
Specific: If you want to filter a specific TCP/UDP destination filter with this
ACE, you can enter a specific TCP/UDP destination value. A field for
entering a TCP/UDP destination value appears.
Range: If you want to filter a specific range TCP/UDP destination filter with
this ACE, you can enter a specific TCP/UDP destination range value. A
field for entering a TCP/UDP destination value appears.
When "Specific" is selected for the TCP/UDP destination filter, you can enter a
specific TCP/UDP destination value. The allowed range is 0 to 65535. A frame
that hits this ACE matches this TCP/UDP destination value.
When "Range" is selected for the TCP/UDP destination filter, you can enter a
specific TCP/UDP destination range value. The allowed range is 0 to 65535. A
frame that hits this ACE matches this TCP/UDP destination value.
Specify the TCP "No more data from sender" (FIN) value for this ACE.
0: TCP frames where the FIN field is set must not be able to match this
entry.
1: TCP frames where the FIN field is set must be able to match this entry.
Any: Any value is allowed ("don't-care").
Specify the TCP "Synchronize sequence numbers" (SYN) value for this ACE.
0: TCP frames where the SYN field is set must not be able to match this
entry.
1: TCP frames where the SYN field is set must be able to match this entry.
Any: Any value is allowed ("don't-care").