4.9.2 Port Policing

This page allows you to configure the Policer settings for all switch ports. The Port Policing screen in
The page includes the following fields:
Object
Port
Enable
Rate
Unit
Flow Control
Buttons
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
Figure 4-9-1: QoS Ingress Port Policers page Screenshot
Description
The port number for which the configuration below applies.
Controls whether the policer is enabled on this switch port.
Controls the rate for the policer. This value is restricted to 100-1000000 when the
"Unit" is "kbps" or "fps", and it is restricted to 1-3300 when the "Unit" is "Mbps"
or "kfps".
The default value is 500.
Controls the unit of measure for the policer rate as kbps, Mbps, fps or kfps .
The default value is "kbps".
If flow control is enabled and the port is in flow control mode, then pause frames
are sent instead of discarding frames.