Planet IGS-5225-16T4S User Manual page 144

Industrial l2+ gigabit ethernet managed switch igs-5225 series
Hide thumbs Also See for IGS-5225-16T4S:
Table of Contents

Advertisement

 Group Name
 Adding a New Group to
VLAN mapping entry
Buttons
: Click to add a new entry in mapping table.
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
Auto-refresh
: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds.
: Click to refresh the page immediately.
a. OUI: OUI (Organizationally Unique Identifier) is value in format of
xx-xx-xx where each pair (xx) in string is a hexadecimal value
ranges from 0x00-0xff.
b. PID: If the OUI is hexadecimal 000000, the protocol ID is the
Ethernet type (EtherType) field value for the protocol running on top
of SNAP; if the OUI is an OUI for a particular organization, the
protocol ID is a value assigned by that organization to the protocol
running on top of SNAP.
In other words, if value of OUI field is 00-00-00 then value of PID will be
etype (0x0600-0xffff) and if value of OUI is other than 00-00-00 then valid
value of PID will be any value from 0x0000 to 0xffff.
A valid Group Name is a unique 16-character long string for every entry which
consists of a combination of alphabets (a-z or A-Z) and integers(0-9).
Note: special character and underscore(_) are not allowed.
Click "Add New Entry"to add a new entry in mapping table. An empty row is
added to the table; Frame Type, Value and the Group Name can be configured
as needed.
The "Delete" button can be used to undo the addition of new entry.
144
User's Manual of IGS-5225 series

Advertisement

Table of Contents
loading

This manual is also suitable for:

Igs-5225-24p4sIgs-5225-20t4c2x

Table of Contents