Parameter List
Parameter
C16
Terminal 1 bias command
(919)
(torque/magnetic flux)
C17
Terminal 1 bias (torque/
(919)
magnetic flux)
C18
Terminal 1 gain command
(920)
(torque/magnetic flux)
C19
Terminal 1 gain (torque/
(920)
magnetic flux)
C38
Terminal 4 bias command
(932)
(torque/magnetic flux)
C39
Terminal 4 bias (torque/
(932)
magnetic flux)
C40
Terminal 4 gain command
(933)
(torque/magnetic flux)
C41
Terminal 4 gain (torque/
(933)
magnetic flux)
989
Parameter for manufacturer setting. Do not set.
990
PU buzzer control
991
PU contrast adjustment
Pr.CL
Parameter clear
ALLC
All parameter clear
Er.CL
Faults history clear
PCPY
Parameter copy
The parameter number in parentheses is the one for use with the parameter unit (FR-PU04/FR-PU07).
140
Incre
Name
ments
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
1
1
1
1
1
1
Initial
Range
Value
Set the torque/magnetic flux command value on the
bias side of terminal 1 input. (valid when Pr. 868 ≠ 0,
0%
0 to 400%
5)
Set the converted % of the bias side voltage
(current) of terminal 1 input. (valid when Pr. 868 ≠ 0,
0%
0 to 300%
5)
Set the torque/magnetic flux command value on the
gain side of terminal 1 input. (valid when Pr. 868 ≠ 0,
150%
0 to 400%
5)
Set the converted % of the gain side voltage
(current) of terminal 1 input. (valid when Pr. 868 ≠ 0,
100%
0 to 300%
5)
Set the torque/magnetic flux command value on the
bias side of terminal 4 input. (valid when Pr. 858 = 1,
0%
0 to 400%
4)
Set the converted % of the bias side current (voltage)
20%
0 to 300%
of terminal 4 input. (valid when Pr. 858 = 1, 4)
Set the torque/magnetic flux command value on the
bias side of terminal 4 input. (valid when Pr. 858 = 1,
150%
0 to 400%
4)
Set the converted % of the gain side current (voltage)
100%
0 to 300%
of terminal 4 input. (valid when Pr. 858 = 1, 4)
0
Without buzzer
1
1
With buzzer
Contrast adjustment of the LCD of the parameter unit
58
0 to 63
(FR-PU04/FR-PU07) can be performed.
0 (Light) → 63 (Dark)
Setting "1" returns all parameters except calibration
0
0, 1
parameters to the initial values.
0
0, 1
Setting "1" returns all parameters to the initial values.
0
0, 1
Setting "1" will clear eight past faults.
0
Cancel
1
Read the source parameters to the operation panel.
0
Write the parameters copied to the operation panel to
2
the destination inverter.
3
Verify parameters in the inverter and operation panel.
Description