Mitsubishi FR-A721-11K Instruction Manual page 135

Inverter fr-a701
Table of Contents

Advertisement

Parameter List
Parameter
286
Droop gain
287
Droop filter time constant
Droop function activation
288
selection
291
Pulse train I/O selection
Input pulse division scaling
384
factor
Frequency for zero input
385
pulse
Frequency for maximum
386
input pulse
292, 293
Refer to Pr. 61.
294
Refer to Pr. 261.
296
Password lock level
297
Password lock/unlock
299
Refer to Pr. 57.
128
Incre
Name
ments
0.1%
0.01s
1
1
1
0.01Hz
0.01Hz
1
1
Initial
Range
Value
0
Droop control is invalid
0%
0.1 to
Set the drooping amount at the rated torque as a
percentage with respect to the rated frequency.
100%
Set the time constant of the primary delay filter
0.3s
0 to 1s
applied to the torque current.
Real sensor less vector /
vector control
Droop control is not
exercised during
acceleration/deceleration.
(When Pr.288 = 10, droop
0, 10
compensation amount is
determined using the
motor speed as
reference.)
Droop control is always
0
exercised during
operation.
(with 0 limit)
1, 11
(When Pr.288 = 11, droop
compensation amount is
determined using the
motor speed as
reference.)
Droop control is always
exercised during
2
operation.
(without 0 limit)
0
JOG terminal
1
Pulse train input
10
JOG terminal
11
Pulse train input
20
JOG terminal
0
21
Pulse train input
100
Indicates division scaling factor to the input pulse and
0
0 to 250
the frequency resolution to the input pulse changes
according to the value.
0
0 to 400Hz Set the frequency when the input pulse is 0 (bias).
Set the frequency when the input pulse is maximum
60Hz
0 to 400Hz
(gain).
0 to 6, 99,
Select restriction level of parameter reading/ writing
100 to 106,
when a password is registered.
9999
199
9999
No password lock
1000 to
Register a 4-digit password
9998
Displays password unlock
error count. (Reading
9999
(0 to 5)*
only)
(Valid when Pr. 296 =
"100" to "106, 199")
9999*
No password lock
Description
Advanced magnetic
flux vector control
Droop control is not
exercised during
acceleration/
deceleration.
Droop compensation
amount is determined
using the rated motor
frequency as reference.
Input
Output
FM output
FM output
Pulse train open collector
output
(50% duty)
Pulse train open collector
output
(ON width is always
same)
Pulse train open collector
output
(ON width is always
same
(independently of Pr. 54))
* "0 or 9999" can be set
in Pr. 297 at any time
although the setting is
invalid (the displayed
value does not
change).