Parameter List
Parameter
RUN terminal function
190
selection
SU terminal function
191
selection
IPF terminal function
192
selection
OL terminal function
193
selection
FU terminal function
194
selection
ABC1 terminal function
195
selection
ABC2 terminal function
196
selection
232 to 239
Refer to Pr. 4 to Pr. 6.
240
Refer to Pr. 72.
241
Refer to Pr. 125 and Pr. 126.
242, 243
Refer to Pr. 73.
124
Incre
Name
ments
1
1
1
1
1
1
1
Initial
Range
Value
0, 100: Inverter running (RUN)
1, 101: Up to frequency (SU)
0
2, 102: Instantaneous power failure/undervoltage
(IPF)
3, 103: Overload warning (OL)
4, 104: Output frequency detection (FU)
5, 105: Second output frequency detection (FU2)
6, 106: Third output frequency detection (FU3)
8, 108: Electronic thermal O/L relay pre-alarm (THP)
10, 110:PU operation mode (PU)
0 to 6, 8,
11, 111: Inverter operation ready (RY)
1
10 to 20,
12, 112:Output current detection (Y12)
25 to 28,
13, 113:Zero current detection (Y13)
30 to 36, 39,
14, 114:PID lower limit (FDN)
41 to 47,
15, 115:PID upper limit (FUP)
64, 70, 84,
16, 116:PID forward/reverse rotation output (RL)
90 to 99,
17, —: Electronic bypass MC1 (MC1)
100 to 106,
18, —: Electronic bypass MC2 (MC2)
108,
19, —: Electronic bypass MC3 (MC3)
2
110 to 116,
20, 120:Brake opening request (BOF)
120,
25, 125:Fan fault output (FAN)
125 to 128,
26, 126:Heatsink overheat pre-alarm (FIN)
130 to 136,
27, 127:Orientation complete (ORA) *
28, 128:Orientation fault (ORM) *
139,
30, 130:Forward rotation output (Y30) *
141 to 147,
31, 131:Reverse rotation output (Y31) *
164, 170,
32, 132:Regenerative status output (Y32) *
184,
3
33, 133:Operation ready 2 (RY2)
190 to 199,
34, 134:Low speed output (LS)
9999
35, 135:Torque detection (TU)
36, 136:In-position (Y36) *
39, 139:Start time tuning completion (Y39)
41, 141:Speed detection (FB)
42, 142:Second speed detection (FB2)
43, 143:Third speed detection (FB3)
44, 144:Inverter running 2 (RUN2)
4
45, 145:Inverter running and start command is ON
(RUN3)
46, 146:During deceleration at occurrence of power
failure (retained until release) (Y46)
47, 147:During PID control activated (PID)
0 to 6, 8,
64, 164:During retry (Y64)
10 to 20,
70, 170:PID output interruption (SLEEP)
25 to 28,
84, 184:Position control preparation ready (RDY) *
30 to 36, 39,
90, 190:Life alarm (Y90)
41 to 47, 64,
91, 191:Fault output 3 (power-off signal) (Y91)
99
70, 84, 90,
92, 192:Energy saving average value updated timing
91,
(Y92)
94 to 99,
93, 193:Current average monitor signal (Y93)
100 to 106,
94, 194:Fault output 2 (ALM2)
95, 195:Maintenance timer signal (Y95)
108,
96, 196:Remote output (REM)
110 to 116,
97, 197:Alarm output 2 (ER)
120,
98, 198:Alarm output (LF)
125 to 128,
99, 199:Fault output (ALM)
130 to 136,
9999:
No function
139,
9999
0 to 99: Positive logic
141 to 147,
100 to 199: Negative logic
164, 170,
* Available only when used with the FR-A7AP/FR-A7AL
184, 190,
(option).
191, 194 to
199, 9999
Description